Leslie a Looney –
Do not buy this unit installed worked great for a few months then all of a sudden throws a bunch of fault codes. Local ac guy comes out needs a new control board to the tune of $1700 new unit was 2200 what a rip off
Franky Bob –
Diagnostic Report for Daikin Install, tested over five days and would not run correctly.
Installed a 2 zone daikin mini—split system for my customer, one unit in the living room,the other in the office, both worked well at the beginning. However, the first day and night, the customer turned the AC off in the living room, only the office AC works, then he saw the blue light flashing and both units wouldn’t turn on.
So I came the next day, the pressure shows 220 PSI when units are turned off, that looks fine. Then I turned both units on, set them at 60F. After that I used my Fieldpiece-DR82 tool to test each connection and I also put soapy water on them, all good, No leaks.
Let them run for 2 hours, all good. Pressure kept between 125-135 during units operation.
Later, I turned off one of the units which is in the living room, went outside to check our pressure gauge, both Vapor line pressure got lower and lower, our office AC still worked, but I could hear the unit which is in the living room still evaporating, after 20 minutes the living room AC’s coil got frozen, then we saw a orange light blinking on the living room AC.
We waited 1 hour, disconnected the power and reset system, turned both units on again, set them at 60f, worked good again, the pressure kept 125-135 for both Vapor line. Looks fine. After 30 minutes, I turned Living room AC off and let the office AC work. The pressure got lower until we saw a frozen coil on the living room AC. Then I turned the living room back on, went outside to check the pressure, it worked well and kept 125-135PSI, the frozen coil melted.
I think the TXV can’t fully turn off because of this fault. We already turned it off but it is still evaporating by itself, but if you turned both units on it should be OK. These are brand new units and my customer wants to return so I didn’t test TXV, or the main Control board
Corey Hart –
Installed by licensed tech on the 24 and totally inoperative by the 3rd day. 23 error codes and 2 tech visits at 75 dollars a pop and they said the unit is no good. Tried leaving messages etc with seller with no luck. Paid almost 2500 plus another grand to have it installed and can’t use it. I’ll update this nice Heat and Cool makes this right. Totally uncalled for.
michael campos –
Little bit of work, if you don’t have havc knowledge don’t try to install. You have to have knowledge on wiring and and make sure you have knowledge of using a vacuuming system
That one guy –
After just a few months, one of the indoor units stopped working. After a $300 visit from my local repair company, I learned that it has a freon leak, which is absurd. I tried to contact the seller, but all I can find is a phone number, and when calling, no one answers, and it never goes to voicemail. I’m going to contact Daikin of course, but it’s very frustrating that I can’t get in touch with the seller at all.
FYI, I have another Daikin elsewhere in my house, and it works like a charm. I like the brand, my problem is with the seller.
Baltimore Gal –
The media could not be loaded.
It is an awesome ac/heat pump combo. It’s very easy to use. I got the unit that was a two zone. It comes with 2 remotes. When I turned the unit on, it was so quite I had to put my hand up to make sure it was on. Definitely worth getting when you don’t have any ductwork. Works 1000 times better then a window unit. This product warranty is through Goodman. Which is a great company. I had it professionally installed. Unless you are an HVAC tech call someone that knows what there doing. Trust me you will be happy!
Amazon Customer –
So important in the south to have a good cooling system. We’ve only had this a couple of weeks, so far it works great.
Helpful? –
Had a professional HVAC company complete the installation. The controll wires were not included.